Can AGM batteries be left on float charge?

AGM batteries were first designed to be float life batteries as used by UPS companies and the telco's. So we're always on float (13.6v) with varying current as required to supply the current draw this is why the VRLA lid is important to capture and recombine those gases/water once recondensed back into the batteries acid.

Auto Electricians Discharge Testing

We have many auto electrical companies that use, buy and ask our advice.

We have this info to offer:

Auto electricians test their batteries for cranking power, the ability to start the vehicle. Even a battery of only half-life remaining will accept a charge and work off an alternator. A CCA test normally indicates a lack of power which is what is required to turn over an engine. Let's not forget they are used to testing start batteries, alternators, and starter motors and their CCA testers are used to test cranking power and not reserve capacity. Many are also advised on what's needed to test by the battery supplier they are affiliated with. Only if they speak to a specialty product manager within the distribution business will they be given info regarding the requirements to discharge test a battery correctly.

We are also aware of one major distributor only using a 75A discharge current to calculate capacity. Many batteries smaller than 100Ah won't even have technical data to support a discharge of this large capacity so the test results aren't accurate.

You need to visit a marine electrician or a well-trained motorhome service centre to get specific info and ensure it's a discharge test done to industry standards. If the test is free it isn't being done right because it takes time and effort to do this properly and most businesses require payment for their services.

Capacity Testing - Discharge testing batteries

You can not test deep cycle batteries with handheld test equipment in a matter of minutes. It takes 8 hours to ensure your batteries are fully charged before spending 8 hours or more discharging them before another 8 hours to recharge. (assuming the batteries are OK), if they cannot hold capacity these tests can be done in hours once you have ensured the battery is first fully charged because the discharge and recharge time will take a much shorter time due to no capacity.

How do you perform a test, there are many variations, some include:

1. Reserve capacity test. Reserve capacity is a discharge at 20deg C and 25A constant for X number of minutes which will be stated on your battery as RC. If RC is 200 then that's 200 minutes at 25A discharge until the battery reaches an end voltage of 10.75v. If your test lasts 100 minutes then your capacity is 50% of its rated new Ah.

2. AH rating test. If a battery is rated at 200Ah @ 20 hours that's 5 amps per hour for 20 hours till an end voltage specified by the battery manufacturer. They often quote in VPC or volts per cell. So for a 12v battery you need to multiply the number by 6. 1.8vpc = 10.8v when testing a 12v battery. You need to discharge a fully charged battery at 5 amps for 20 hours and if the battery lasts 10 hours before the voltage reaches 10.8v then that's 50% of its rated capacity.

3. Not recommended but some distributors supply 75A discharge testers because that's a test used on golf cart batteries that they distribute. Golf cart batteries are also normally 6v 250Ah or larger (can be 415Ah) so a 75A discharge test is only 1/2 or less the batteries rated capacity. If you perform a 75A constant current discharge test on a 100Ah battery you certainly aren't going to get a real-world test result on a 100Ah battery when the test would only last 30 mins on a brand new healthy battery but your tested battery only lasts say 17 mins. It's easy to quote a large percentage number differential or failure when you've only tested for a few minutes and each minute represents 2-3%. So this test needs to be put in perspective of reliability to your situation. It is, however, a great way to ensure you buy a new battery from the battery test company.

Last point, a discharge test is using a deep cycle, your battery only has X number of those depending on how you've used your battery so they really only need to be done when there's an issue or if performing a system upgrade and you want to assess the suitability of the batteries to perform their new duties.

Ampere Ratings or Amp Hour Rates

Batteries are classed, categorised and rated to international standards. Those standards can also be manipulated when published if you state your variances, the trick is to know what's important and why.

In the Aviation industry battery is rated at the 1 hour rate because if your batteries fail while in flight you better hope you can get on the ground within 30 minutes before you lose communication or navigation instrumentation. This means a battery rated a 10Ah @ the 1-hour rate can provide 10A until it's voltage reaches 10.02 volts or 1.67 volt per cell and is considered completely flat. (sometimes the end voltages are much lower to make a batteries capacity seem better).

Traction batteries like used in Electric Forklifts are rated at a 5 or 8-hour rate because depending on the type of products being picked the equipment might average 5 used hours in one shift. Other products might require more handling in an 8-hour shift so you would use the 8 hour rate. Either way the end result would be flat batteries by the end of shift, which once recharged is 1 cycle. If you use larger batteries you can lift the depth of discharge from say 50% to 60% and that will manipulate the depth of discharge (end voltage when flat) and the increased cycle life from say 2000 cycles to 2500 cycles will extend the replacement time (in years) and your Return On Investment (R.O.I).

Industrial Applications use power over a working day with lunch breaks so a 10 hour rate is used. i.e. 18Ah battery at the 10 hour rate will provide 1.8A of power for 10 hours until the voltage is reduced to 10.02 volts. (If the temperature is higher or lower it will change the batteries rated capacity).

General use, deep cycle & Automotive/Marine batteries use the 20 hour rate or Amps over 20 hours so again you divide the stated Ah by 20 hours to get the average current discharge per hour. 100Ah / 20 hours = 5 Amps per hour. (All to often we see all the ampere ratings, temps, end voltages, and battery purposes cross over to confuse and or mislead a buyer as to how good a battery will perform not to mention the variations in a batteries weight).

Solar use the 24 hour rate for daily averages, but the 100 hour rate or 120 hour rate are more common as they refer to a better average use over 4 or 5 days.

You can see how when batteries are advertised at a rate that differs from these industry standards that the designed purpose of the battery may have been for a different use and that it may mean the charging rates need to be different, the voltages might need to be different or that the cycle life could be more or less than your expected use with consequences good or bad.

What does AGM mean?

Absorbed Glass Matt - its a type of Lead-acid battery. There is a microfibrous matting placed between each plate to ensure there is no shorting of the plates. AGM batteries are commonly confused with Gel batteries (which look similar but have a different usable purpose).

Depth of Discharge explained.

Depth of Discharge is something that's relevant to all rechargeable batteries. This type of battery is specifically designed to perform and discharge before being recharged and is commonly referred to as a deep cycle battery.

Deep cycle batteries quite often don't advertise a CCA (cold cranking) rating as this is more typical with starting batteries. Dual-purpose batteries like some AGM batteries, however, have good deep cycle ability and a large surface area of active material which gives them high cranking output when compared to equivalent-sized starting batteries. Remember, the purpose of the battery is the most important consideration here.

Battery spec sheets of deep cycle batteries will show a cycle life that is expressed by a graph showing different depths of discharge with a corresponding life expectancy. When the depth of discharge is deeper the number of times that battery can cycle reduces. So general-purpose batteries might only be 50-70 cycles at 30% depth of discharge. These are sometimes referred to as Leisure batteries but in fact, are just standard typical starting batteries. 400 cycles at 50% D.O.D. is really where a purpose-built battery might be advertised as a deep cycle. This will extend to 80% D.O.D at 700-800 cycles before you get to the internationally recognised quality brands that might be as much as 1000-1200 cycles at 50% which is similar on the graph to the 80% at 700 cycles but shows the manufacturers intent of the battery to be longer-lasting over 1200 cycles than say once a day for 2 years until end of life.

State of Charge vs. Depth of Discharge

State of charge refers to how high a percentage of fully charged a battery is. An example would be if you were to discharge 25% of a batteries capacity the battery would be 75% S.O.C (state of charge). The same example would show a 25% depth of discharge.

Start Stop Technology what is it?

Start Stop refers to a vehicle's engine stopping when a vehicle comes to a standstill and restarts automatically when the driver releases the brake or presses the accelerator.

Page 2 of 3