The M200 charges and analyses in eight fully automatic steps.
The M200 charges and analyses in eight fully automatic steps.
Batteries
The M200 can be set very easily to charge different types of lead-acid batteries (Wet, MF, GEL and AGM) and conditions. You will find an explanation of the various battery types under Charger University, Battery Types.
The M200 charges a wide range of battery sizes, from 28Ah to 300Ah.
| SETTINGS |
EXPLANATION |
| NORMAL |
Normal setting for wet batteries, maintenance free and for most Gel batteries. Some Gel batteries prefer a slightly lower charging voltage. Please consult the battery manufacturer when in doubt. |
| NIGHT |
This mode is equal to NORMAL, but with reduced current. The built-in fan is disabled and the unit is almost silent. The Unit returns automatically to NORMAL after 8 hours. To ensure that the charger restarts in NIGHT mode in the event of a power failure the setting is stored in a memory. The indication shows “NIGHT” even if the charger has returned to NORMAL mode to remind that the charger will start in NIGHT mode next time. |
| RECOND |
This mode is used to recover deep discharged flooded batteries where you could expect a stratified acid (high acid weight in the bottom, low on top). Check with battery manufacturer when in doubt. Use this mode with care, because the high voltage will cause some water loss. 16V is normally no problem for electronics in 12V system. Consult your supplier when in doubt. Life of light bulbs will be reduced at higher voltage. Try to disconnect light from the battery during this phase. Maximum effect and minimum risk for electronics is achieved by charging a disconnected battery. |
| BULK CHARGE TIME |
| BATTERY SIZE (Ah) |
FOR ABOUT 80% CHARGE (h) |
| 60 |
3 |
| 100 |
5 |
| 150 |
0 |
| 300 |
16 |